Movincool Office Pro 60 Specifiche

Navigare online o scaricare Specifiche per Climatizzatori a split Movincool Office Pro 60. Movincool Office Pro 60 Specifications Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Technical Services Department
DSCA P/N: LA990009-1219 Third Issue: March 2003
GAC P/N: LA484007-1441 Printed in the U.S.A.
DENSO SALES CALIFORNIA, INC.
3900 Via Oro Avenue
Long Beach CA 90810-1868
800-264-9573 / 310-834-6352
www.movincool.com
OPERATION MANUAL
OFFICE PRO 60
READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT
INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.
POSTAGE WILL BE PAID BY ADRESSEE
FIRST-CLASS MAIL PERMIT NO. 8390 LONG BEACH, CA
BUSINESS REPLY MAIL
DENSO SALES CALIFORNIA, INC. INC.
3900 VIA ORO AVENUE
LONG BEACH, CA 90810-9969
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
SECCIÓN EN ESPAÑOL
SECTION EN FRANÇAIS
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - OPERATION MANUAL

Technical Services DepartmentDSCA P/N: LA990009-1219 Third Issue: March 2003GAC P/N: LA484007-1441 Printed in the U.S.A.DENSO SALES CALIFORNIA, INC.39

Pagina 2 - LIMITED WARRANTY

INSTALLATIONChoosing an Installation SiteCAUTION: Following are some precautions to consider beforechoosing your installation site. Please review car

Pagina 3

INSTALLATION (cont.)Moving the UnitUnlock the casters and push the MovinCool unit, using the side handles,to a flat, level surface and set the casters

Pagina 4

INSTALLATION (cont.)Plugging in the Unit• Check the prongs and surface of the power cord plug for dust/dirt. Ifdust and/or dirt are present, wipe off

Pagina 5 - TABLE OF CONTENTS

FEATURESOP60 Features• An electronic control panel which allows the user to control theunit’s operation easily.• Dual fan speeds (either High or Low)

Pagina 6

TANKFULLSET POINTFCROOM TEMPAMPMSET TEMP CLOCK/TIMERFAN ON/OFFCOOL ON/OFF PROGRAMOffice Pro 60SETSTART TIMEEND TIMESET CLOCKRUNHRS MIN654321OPERATIONC

Pagina 7 - FOREWORD

OPERATION (cont.)Control Panel (Cont.)➆ Temperature Scale Illuminates to indicate the currentLED temperatures being displayed areeither in °C or °F; a

Pagina 8

OPERATION (cont.)Operating in COOL Mode➀ The unit can be operated in COOL mode by pressing the COOLON/OFF button (LED illuminates).NOTE: In COOL mode

Pagina 9 - INVENTORY

OPERATION (cont.)How to Set a Program➀ Setting a START TIMEPress the Program SET button. The Program SET button and STARTTIME LEDs will illuminate. Pr

Pagina 10 - INSTALLATION

OPERATION (cont.)How to Set a Program (Cont.)NOTE:• The unit will return to the previous mode if a program is turnedoff while it is running.• The Prog

Pagina 11 - INSTALLATION (cont.)

OPERATION (cont.)Operating ModesOffice Pro 60 operates in 2 modes, FAN Only and COOL. When in FANOnly mode, the unit circulates the surrounding air. W

Pagina 12

LIMITED WARRANTYDENSO SALES CALIFORNIA, INC. ("DENSO") warrants its MOVINCOOLProducts only to the extent stated in its official written warr

Pagina 13 - FEATURES

OPERATION (cont.)Emptying the Drain Tank (If equipped)During COOL mode, condensate will accumulate in the drain tank.When the drain tank becomes full,

Pagina 14 - OPERATION

ABOPERATION (cont.)Drain PumpA drain pump is included to allow continuous operation and to eliminatethe need for a drain tank.• When the water collect

Pagina 15 - OPERATION (cont.)

HOSE INSTALLATIONNote: The OP60 is equipped with a20 foot (6 m) hose.Connect the 20 foot (6 m) hose tothe drain outlet spout and feed itthrough the gr

Pagina 16

DAILY INSPECTION & MAINTENANCEEmptying the Drain TankTo empty the drain tank, refer to instructions, page 14.Cleaning the Air FiltersClean the air

Pagina 17

DAILY INSPECTION & MAINTENANCE (cont.)Cleaning Method➀ Remove dust from the elementwith a vacuum cleaner, or rinsein cold or lukewarm water. If th

Pagina 18

TROUBLESHOOTINGOffice Pro 60 Self-Diagnostic CodesSelf-Diagnostic Codes will be displayed on the Control Board underthe following conditions:TANKFULLS

Pagina 19

TECHNICAL SPECIFICATIONSITEM/FEATURES OFFICE PRO 60Rating Conditionsdry bulb 95º F (35º C)wet bulb 83º F (28.2º C)humidity 60%Specificationspower freq

Pagina 20

LIMITED WARRANTYDENSO SALES CALIFORNIA, INC. ("DENSO") warrants its MOVINCOOLProducts only to the extent stated in its official written warr

Pagina 21

Technical Services DepartmentDSCA P/N: LA990009-1219 Third Issue: March 2003GAC P/N: LA484007-1441 Printed in the U.S.A.DENSO SALES CALIFORNIA, INC.39

Pagina 22 - DRAIN HOSE

OPERATION MANUALOFFICE PRO 60

Pagina 24

TABLE OF CONTENTSFOREWORD ... 1Definition of Terms ...

Pagina 26 - TECHNICAL SPECIFICATIONS

FOREWORDCongratulations on purchasing the MovinCool portable air conditioner.This manual explains how to assemble, install and operate theMovinCool Of

Pagina 27

GENERAL WARNINGS & CAUTIONS• All electrical work, if necessary, should only be performed byqualified electrical personnel. Repair to electrical co

Pagina 28

INVENTORYAfter unpacking your MovinCool unit, please check to make sure youhave the following items:•Office Pro 60 MovinCool Unit (1)• Operation Manua